How to Select the Best Automatic Transfer Switch

Power outages can disrupt everyday life and cause significant problems, especially in facilities like hospitals, schools, and labs, where continuous power is essential. Research shows that the average power outage costs businesses thousands per hour.

To prevent these interruptions, an automatic transfer switch is safeguarded by switching to a backup power source like a generator.

This guide will help you understand what to look for in an ATS, covering its purpose, technical factors, and practical installation steps.

What Are Transfer Switches?

A transfer switch is installed between the main power supply, usually the utility grid, and a backup power source, like a generator. It allows for a safe and controlled switch from one power source to another during an outage.

Transfer switches come in two main types:

1. Manual Transfer Switches

Require someone to operate them manually, meaning someone has to flip a switch to transfer power to a backup generator when the main power fails. They are often used in smaller, less critical setups where power downtime is manageable.

2. Automatic Transfer Switches

These devices are designed to sense a power failure and automatically transfer the power load to a backup source without any manual intervention. They are ideal for locations where quick power restoration is crucial, such as hospitals, data centers, and other essential facilities.

Factors to Consider While Selecting the Best Automatic Transfer Switch

Choosing an ATS involves understanding several technical aspects and knowing what specifications will best fit your needs. Here are some of the main factors to consider.

1. Load Types

Knowing the types of loads the ATS will manage is essential for choosing the right switch. Understanding the load types in your setup helps determine the best automatic transfer switch for your needs.

Loads generally fall into two categories:

  • Resistive Loads: These are simple, steady loads like lights, heaters, and other devices that don’t need extra power to start up. Resistive loads are straightforward for an ATS to handle because they draw a constant amount of power.
  • Inductive Loads: These loads, such as motors, air conditioners, and compressors, require a significant surge of power when they start up, often up to three times the operating power.

2. Electrical Current

The electrical current rating of an ATS, measured in amperes (amps), is one of the most critical specifications. To ensure reliable operation, an ATS must match or exceed the highest current requirement in your setup. Choosing an undersized ATS can lead to equipment failure or even pose a safety risk due to overloading.

3. Voltage

The voltage rating of an ATS should match the voltage requirements of the generator and the main power supply. This ensures compatibility and safe operation. Here’s a quick breakdown:

  • Residential systems often run on 120/240 volts in the U.S. and 220 volts in many European countries.
  • Commercial and industrial systems can vary widely, with common setups needing 208/120V or 480/277V.

4. Power Measurement

Some ATS models include power monitoring and measurement functions. While this feature might not be necessary for all users, it can be valuable in more extensive setups too:

  • Monitor the power load on the generator.
  • Identify opportunities for power optimization.
  • Prevent overload situations by tracking consumption in real time.

Essential Transfer Switch Installation Tips You Should Know

Installing an ATS requires precision and following safety guidelines. Below are some transfer switch installation tips to help you get it right. If you’re unfamiliar with electrical work, hiring a licensed electrician is highly recommended for safe installation.

1. Choose the Right Transfer Switch

Before anything else, ensure you have the correct ATS model based on the abovementioned factors. Verify that the ATS can handle your facility’s load, current, and voltage requirements.

2. Decide on the Location

Choosing the right location is crucial for safe and effective installation. Here’s what to consider:

  • Proximity to Main Power and Generator: The ATS is usually installed near the main electrical panel or generator. This location minimizes the wiring distance, which helps reduce electrical resistance and ensures efficient operation.
  • Ventilation and Dry Conditions: Choose a spot free from moisture and excessive heat. Proper ventilation keeps the ATS cool, extending its life.
  • Clear Identification: In an emergency, labeling the ATS location helps emergency personnel quickly identify it. It’s also helpful for maintenance personnel.

3. Shut Off Power

For safety, shut off all power sources to avoid electrical hazards. Locking out the power source prevents accidental reactivation during installation, protecting everyone involved in the process.

4. Follow Installation Protocols

An ATS installation should comply with local electrical codes. Most ATS devices come with a manufacturer’s manual that includes wiring diagrams and step-by-step instructions.

Here are some critical protocols to follow:

  • Connect Wires Correctly: Using the wiring diagram, connect each wire properly. Improper wiring can lead to equipment damage and even pose a fire risk.
  • Grounding Requirements: Proper grounding is essential to prevent electrical buildup. Ground the ATS according to the specifications provided in the manual.
  • Configure Power Thresholds (If Applicable): Some ATS models allow you to set switching thresholds (the points at which the ATS will switch to generator power). Configure these thresholds based on your facility’s needs.

5. Perform a Final Test

After installation, testing the ATS to confirm that it works as intended is crucial. Here’s how to do it:

  • Simulate a Power Outage: Turn off the main power to see if the ATS automatically switches to the generator.
  • Observe the Transition: The ATS should connect the generator power without delay and with no issues.
  • Return to Main Power: Once the main power is restored, the ATS should return to its default position, disconnecting the generator.

Wrap Up

The best automatic transfer switch for your setup depends on various factors, from load types to electrical requirements and installation location. By understanding these essential elements, you can select an ATS that meets your needs for uninterrupted power.

With the right ATS, you can confidently handle unexpected power outages, keeping essential operations running smoothly and minimizing downtime.